Supreme

    Yokogawa supreme Coriolis mass flow meter is the most accurate type with industry’s best zero stability. 
    Brand: Yokogawa 
    Place of origin: Germany 
    Delivery: 8 to 10 weeks

General introduction

Supreme Coriolis mass flow meter is for accurate flow applications, typical line sizes: DN15, DN25, DN40, DN50, DN65, DN80, DN100, DN125, 1/4”, 1/2”, 1”, 1 1/2”, 2”, 3”, 4”, 5”and maximum mass flow up to 170 t/h and volume up to 170 m3/h, delivers unsurpassed performance for demanding and critical applications with superior aeration handling and advanced diagnostic functionality.

Measuring range limits 

Meter size

Normal Mass Flow

Maximum mass flow

Normal Volume flow

Max Volume flow

Normal Temperature

Max. Temperature

Density

Supreme 34

3 t/h

5 t/h

3 m3/h

5 m3/h

-50 to150℃

-70 to 350℃

0 to 5 kg/l

Supreme 36

10 t/h

17 t/h

10 m3/h

17 m3/h

Supreme 38

32 t/h

50 t/h

32 m3/h

50 m3/h

0 to 2 kg/l

Supreme 39

100 t/h

170 t/h

100 m3/h

170 m3/h

3. Accuracy of liquids Measurement

Measured quantity

Accuracy for transmitters

Essential

Ultimate

Mass flow

Accuracy

0.15 % of measured value

0.1 % of measured value

Repeatability

0.08 % of measured value

0.05 % of measured value

Volume flow

Accuracy

0.43 % of measured value

0.12 % of measured value

Repeatability

0.22 % of measured value

0.06 % of measured value

Density

Accuracy

4 g/l (0.25 lb/ft³)

0.5 g/l (0.03 lb/ft³)

Repeatability

2 g/l (0.13 lb/ft³)

0.3 g/l (0.02 lb/ft³)

Temperature

Accuracy

0.5℃ (0.9℉)

0.5℃ (0.9℉)

4. Accuracy of gas Measurement

Measured quantity

Accuracy for transmitters

Essential

Ultimate

Mass flow

Accuracy

0.75 % of measured value

0.5 % of measured value

Repeatability

0.6 % of measured value

0.4 % of measured value

Volume flow

Accuracy

0.75 % of measured value

0.5 % of measured value

Repeatability

0.6 % of measured value

0.4 % of measured value

Temperature

Accuracy

0.5℃ (0.9℉)

0.5℃ (0.9℉)

5. Model selection of Supreme 34

Main Code

Suffix Codes

Description

RC















Always RC

Transmitter

E














Essential (base function)

U














Ultimate (high function)

Sensor


S













Supreme

Meter size



34












Nominal mass flow : 3 t/h (110 lb/min), Maximum mass   flow: 5 t/h (180 lb/min)

Material of   wetted parts




S











Stainless steel 1.4404/316L




H











Ni alloy C-22/2.4602

Process   connection size





08










⅜"





15










DN15, ½"





20










¾"





25










DN25, 1"





40










DN40, 1½"





50










2"

Process   connection type






BA1









ASME flange class 150, suitable for ASME   B16.5, raised face (RF)






BA2









ASME flange class 300, suitable for ASME   B16.5, raised face (RF)






BA4









ASME flange class 600, suitable for ASME   B16.5, raised face (RF)






CA4









ASME flange class 600, suitable for ASME   B16.5, ring joint (RJ)






BD4









EN flange PN 40, suitable for EN 1092-1   type B1, raised face (RF)






ED4









EN flange PN 40, suitable for EN 1092-1   type E, spigot






FD4









EN flange PN 40, suitable for EN 1092-1   type F, recess






GD4









EN flange PN 40, suitable for EN 1092-1   type D, groove






BD6









EN flange PN 100, suitable for EN 1092-1   type B1, raised face (RF)






ED6









EN flange PN 100, suitable for EN 1092-1   type E, spigot






FD6









EN flange PN 100, suitable for EN 1092-1   type F, recess






GD6









EN flange PN 100, suitable for EN 1092-1   type D, groove






BJ1









JIS flange 10K, JIS B 2220






BJ2









JIS flange 20K, JIS B 2220






BP1









JPI flange class 150






BP2









JPI flange class 300






BP4









JPI flange class 600






TG9









Process connection with internal thread   G






TT9









Process connection with internal thread   NPT






HS4









Clamp process connection according to   DIN 32676 series A






HS8









Clamp process connection according to   DIN 32676 series C (Tri-Clamp)






HS9









Clamp process connection according to   JIS/ISO 2852

Sensor housing 0material







0








Stainless steel 1.4301/304, 1.4404/316L







1








Stainless steel 1.4404/316L

Process fluid   temperature range








0







Standard integrate: -50 to 150℃ (-58 to 302℉), remote type:   -70 to 200 °C (-94 – 392 °F)








2







Mid-range: -70 to 230℃ (-94 to 446℉)








3







High: 0 to 350℃ (32 to 662℉)

Mass flow and   density accuracy









E7






Liquid: 0.2 % maximum mass flow   deviation, 4 g/l density deviation









D7






Liquid: 0.15 % maximum mass flow   deviation, 4 g/l density deviation









C6






Liquid: 0.1 % maximum mass flow   deviation, 3 g/l density deviation









C3






Liquid: 0.1 % maximum mass flow deviation, 1 g/l density   deviation









C2






Liquid: 0.1 % maximum mass flow deviation, 0.5 g/l   density deviation









70






Gas: 0.75% maximum mass flow deviation









50






Gas: 0.5% maximum mass flow deviation

Design and   housing










0





Integral type with "urethane-cured   polyester powder coating" coated aluminum transmitter housing










2





Integral type with "corrosion   protection coating" coated aluminum transmitter housing










A





Remote type with "urethane-cured   polyester powder coating" coated aluminum transmitter housing and   standard neck sensor










B





Remote type with "urethane-cured   polyester powder coating" coated aluminum transmitter housing and long   neck sensor










E





Remote type with "corrosion   protection coating" coated aluminum transmitter housing and standard   neck sensor










F





Remote type with "corrosion   protection coating" coated aluminum transmitter housing and long neck   sensor










J





Remote type stainless steel transmitter   and standard neck sensor










K





Remote type stainless steel transmitter   and long neck sensor

Ex approval











NN00




None











KF21




ATEX, explosion group IIC and IIIC











KF22




ATEX, explosion group IIB and IIIC











SF21




IECEx, explosion group IIC and IIIC











SF22




IECEx, explosion group IIB and IIIC











GF21




EAC Ex, explosion group IIC and IIIC











GF22




EAC Ex, explosion group IIB and IIIC











FF11




FM, groups A, B, C, D, E, F, G











FF12




FM, groups C, D, E, F, G











UF21




INMETRO, explosion group IIC and IIIC











UF22




INMETRO, explosion group IIB and IIIC











NF21




NEPSI, explosion group IIC and IIIC











NF22




NEPSI, explosion group IIB and IIIC











PF21




Korea Ex, explosion group IIC and IIIC











PF22




Korea Ex, explosion group IIB and IIIC

Cable entries












2



ANSI ½" NPT












4



ISO M20x1.5

Communication   type and I/O













JA


active current output HART,1 passive   pulse or status output













JB


2 active current outputs one with HART,2   passive pulse or status outputs













JC


2 active current outputs one with HART,1   passive pulse or status output,1 voltage-free status input













JD


1 active current output HART,2 passive   pulse or status outputs,1 passive status output













JE


1 active current output HART,2 passive   pulse or status outputs,1 voltage-free status input













JF


1 active current output HART,1 passive   pulse or status output,1 active pulse or status output with pull-up   resistor,1 voltage-free status input













JG


1 active current output HART,1 passive   pulse or status output,1 active pulse or status output,1 voltage-free status   input













JH


1 active current output HART,1 passive   pulse or status output,1 passive current output,1 active current input













JJ


1 active current output HART,2 passive   pulse or status outputs,1 active current input













JK


1 active current output HART,1 passive   pulse or status output,1 voltage-free status input,1 active current input













JL


1 active current output HART,1 passive   pulse or status output,1 passive current output,1 passive current input













JM


1 active current output HART, 2 passive   pulse or status outputs,1 passive current input













JN


1 active current output HART,1 passive   pulse or status output,1 voltage-free status input,1 passive current input













JP


2 passive current outputs one with   HART,1 passive pulse or status output













JQ


2 passive current outputs one with   HART,2 passive pulse or status outputs













JR


2 passive current outputs one with HART,1   passive NAMUR pulse or status output













JS


2 passive current outputs one with   HART,2 passive NAMUR pulse or status outputs













M0


Modbus output,1 passive pulse or status   output













M2


Modbus output,1 passive pulse or status   output,1 active current input













M3


Modbus output, 2 passive pulse or status   outputs













M4


Modbus output,1 passive pulse or status   output, 1 active pulse or status output













M5


Modbus output, 1 passive pulse or status   output, 1 active pulse or status output with pull-up resistor













M6


Modbus output,1 passive pulse or status   output, 1 active current output













M7


Modbus output, 1 passive pulse or status   output, 1 passive current input

Display














0

No display














1

With display

Optional codes

/Optional codes

6. Model selection of Supreme 36

Main Code

Suffix Codes

Description

RC















Always RC

Transmitter

E














Essential (base function)

U














Ultimate (high function)

Sensor


S













Supreme

Meter size



36












Nominal mass flow : 10 t/h (370 lb/min),   Maximum mass flow: 17 t/h (620 lb/min)

Material of wetted parts




S











Stainless steel 1.4404/316L




H











Ni alloy C-22/2.4602

Process   connection size





25










DN25, 1"





40










DN40, 1½"





50










2"

Process connection type






BA1









ASME flange   class 150, suitable for ASME B16.5, raised face (RF)






BA2









ASME flange class   300, suitable for ASME B16.5, raised face (RF)






BA4









ASME flange   class 600, suitable for ASME B16.5, raised face (RF)






CA4









ASME flange   class 600, suitable for ASME B16.5, ring joint (RJ)






BD4









EN flange PN 40,   suitable for EN 1092-1 type B1, raised face (RF)






ED4









EN flange PN 40,   suitable for EN 1092-1 type E, spigot






FD4









EN flange PN 40,   suitable for EN 1092-1 type F, recess






GD4









EN flange PN 40,   suitable for EN 1092-1 type D, groove






BD6









EN flange PN   100, suitable for EN 1092-1 type B1, raised face (RF)






ED6









EN flange PN   100, suitable for EN 1092-1 type E, spigot






FD6









EN flange PN   100, suitable for EN 1092-1 type F, recess






GD6









EN flange PN   100, suitable for EN 1092-1 type D, groove






BJ1









JIS flange 10K,   JIS B 2220






BJ2









JIS flange 20K,   JIS B 2220






BP1









JPI flange class   150






BP2









JPI flange class   300






BP4









JPI flange class   600






TG9









Process   connection with internal thread G






TT9









Process   connection with internal thread NPT






HS4









Clamp process   connection according to DIN 32676 series A






HS8









Clamp process connection according to DIN 32676 series C (Tri-Clamp)






HS9









Clamp process   connection according to JIS/ISO 2852

Sensor housing 0material







0








Stainless steel 1.4301/304, 1.4404/316L







1








Stainless steel 1.4404/316L

Process fluid temperature range








0







Standard   integrate: -50 to 150℃ (-58 to 302℉), remote type: -70 to 200 °C (-94 – 392 °F)








2







Mid-range: -70 to   230℃ (-94 to 446℉)








3







High: 0 to 350℃ (32 to 662℉)

Mass flow and density accuracy









E7






Liquid: 0.2 %   maximum mass flow deviation, 4 g/l density deviation









D7






Liquid: 0.15 %   maximum mass flow deviation, 4 g/l density deviation









C6






Liquid: 0.1 %   maximum mass flow deviation, 3 g/l density deviation









C3






Liquid: 0.1 % maximum mass flow   deviation, 1 g/l density deviation









C2






Liquid: 0.1 % maximum mass flow   deviation, 0.5 g/l density deviation









70






Gas: 0.75% maximum mass flow deviation









50






Gas: 0.5% maximum mass flow deviation

Design and housing










0





Integral type with "urethane-cured polyester powder coating" coated   aluminum transmitter housing










2





Integral type with "corrosion protection coating" coated   aluminum transmitter housing










A





Remote type with "urethane-cured polyester powder coating" coated   aluminum transmitter housing and standard neck sensor










B





Remote type with "urethane-cured polyester powder coating" coated   aluminum transmitter housing and long neck sensor










E





Remote type with "corrosion protection coating" coated   aluminum transmitter housing and standard neck sensor










F





Remote type with "corrosion protection coating" coated   aluminum transmitter housing and long neck sensor










J





Remote type stainless steel transmitter and standard neck sensor










K





Remote type stainless steel transmitter and long neck sensor

Ex approval











NN00




None











KF21




ATEX, explosion group IIC and IIIC











KF22




ATEX, explosion group IIB and IIIC











SF21




IECEx, explosion group IIC and IIIC











SF22




IECEx, explosion group IIB and IIIC











GF21




EAC Ex, explosion group IIC and IIIC











GF22




EAC Ex, explosion group IIB and IIIC











FF11




FM, groups A, B, C, D, E, F, G











FF12




FM, groups C, D, E, F, G











UF21




INMETRO, explosion group IIC and IIIC











UF22




INMETRO, explosion group IIB and IIIC











NF21




NEPSI, explosion group IIC and IIIC











NF22




NEPSI, explosion group IIB and IIIC











PF21




Korea Ex, explosion group IIC and IIIC











PF22




Korea Ex, explosion group IIB and IIIC

Cable entries












2



ANSI ½" NPT












4



ISO M20x1.5

Communication type and I/O













JA


active current   output HART,1 passive pulse or status output













JB


2 active current   outputs one with HART,2 passive pulse or status outputs













JC


2 active current   outputs one with HART,1 passive pulse or status output,1 voltage-free status   input













JD


1 active current   output HART,2 passive pulse or status outputs,1 passive status output













JE


1 active current   output HART,2 passive pulse or status outputs,1 voltage-free status input













JF


1 active current   output HART,1 passive pulse or status output,1 active pulse or status output   with pull-up resistor,1 voltage-free status input













JG


1 active current   output HART,1 passive pulse or status output,1 active pulse or status   output,1 voltage-free status input













JH


1 active current   output HART,1 passive pulse or status output,1 passive current output,1   active current input













JJ


1 active current   output HART,2 passive pulse or status outputs,1 active current input













JK


1 active current   output HART,1 passive pulse or status output,1 voltage-free status input,1   active current input













JL


1 active current   output HART,1 passive pulse or status output,1 passive current output,1   passive current input













JM


1 active current   output HART, 2 passive pulse or status outputs,1 passive current input













JN


1 active current   output HART,1 passive pulse or status output,1 voltage-free status input,1   passive current input













JP


2 passive   current outputs one with HART,1 passive pulse or status output













JQ


2 passive   current outputs one with HART,2 passive pulse or status outputs













JR


2 passive   current outputs one with HART,1 passive NAMUR pulse or status output













JS


2 passive   current outputs one with HART,2 passive NAMUR pulse or status outputs













M0


Modbus output,1   passive pulse or status output













M2


Modbus output,1   passive pulse or status output,1 active current input













M3


Modbus output, 2   passive pulse or status outputs













M4


Modbus output,1   passive pulse or status output, 1 active pulse or status output













M5


Modbus output, 1   passive pulse or status output, 1 active pulse or status output with pull-up   resistor













M6


Modbus output,1   passive pulse or status output, 1 active current output













M7


Modbus output, 1   passive pulse or status output, 1 passive current input

Display














0

No display














1

With display

Optional codes

/Optional codes

7. Model selection of Supreme 38

Main Code

Suffix Codes

Description

RC















Always RC

Transmitter

E














Essential (base function)

U














Ultimate (high function)

Sensor


S













Supreme

Meter size



38












Nominal mass flow : 32 t/h (1200   lb/min), Maximum mass flow: 50 t/h (1800 lb/min)

Material of wetted parts




S











Stainless steel 1.4404/316L




H











Ni alloy C-22/2.4602

Process connection size





40










DN40, 1½"





50










2"





65










DN65, 2½"





80










DN80, 3"

Process connection type






BA1









ASME flange class   150, suitable for ASME B16.5, raised face (RF)






BA2









ASME flange   class 300, suitable for ASME B16.5, raised face (RF)






BA4









ASME flange   class 600, suitable for ASME B16.5, raised face (RF)






CA4









ASME flange   class 600, suitable for ASME B16.5, ring joint (RJ)






BD4









EN flange PN 40,   suitable for EN 1092-1 type B1, raised face (RF)






ED4









EN flange PN 40,   suitable for EN 1092-1 type E, spigot






FD4









EN flange PN 40,   suitable for EN 1092-1 type F, recess






GD4









EN flange PN 40,   suitable for EN 1092-1 type D, groove






BD6









EN flange PN   100, suitable for EN 1092-1 type B1, raised face (RF)






ED6









EN flange PN   100, suitable for EN 1092-1 type E, spigot






FD6









EN flange PN   100, suitable for EN 1092-1 type F, recess






GD6









EN flange PN   100, suitable for EN 1092-1 type D, groove






BJ1









JIS flange 10K,   JIS B 2220






BJ2









JIS flange 20K,   JIS B 2220






BP1









JPI flange class   150






BP2









JPI flange class   300






BP4









JPI flange class   600






TG9









Process   connection with internal thread G






TT9









Process   connection with internal thread NPT






HS4









Clamp process   connection according to DIN 32676 series A






HS8









Clamp process connection according to DIN 32676 series C (Tri-Clamp)






HS9









Clamp process   connection according to JIS/ISO 2852

Sensor housing 0material







0








Stainless steel 1.4301/304, 1.4404/316L







1








Stainless steel 1.4404/316L

Process fluid temperature range








0







Standard   integrate: -50 to 150℃ (-58 to 302℉), remote type: -70 to 200 °C (-94 – 392 °F)








2







Mid-range: -70   to 230℃ (-94 to 446℉)








3







High: 0 to 350℃ (32 to 662℉)

Mass flow and density accuracy









E7






Liquid: 0.2 %   maximum mass flow deviation, 4 g/l density deviation









D7






Liquid: 0.15 %   maximum mass flow deviation, 4 g/l density deviation









C6






Liquid: 0.1 %   maximum mass flow deviation, 3 g/l density deviation









C3






Liquid: 0.1 % maximum mass flow   deviation, 1 g/l density deviation









C2






Liquid: 0.1 % maximum mass flow   deviation, 0.5 g/l density deviation









70






Gas: 0.75% maximum mass flow deviation









50






Gas: 0.5% maximum mass flow deviation

Design and housing










0





Integral type with "urethane-cured polyester powder coating"   coated aluminum transmitter housing










2





Integral type with "corrosion protection coating" coated   aluminum transmitter housing










A





Remote type with "urethane-cured polyester powder coating"   coated aluminum transmitter housing and standard neck sensor










B





Remote type with "urethane-cured polyester powder coating"   coated aluminum transmitter housing and long neck sensor










E





Remote type with "corrosion protection coating" coated   aluminum transmitter housing and standard neck sensor










F





Remote type with "corrosion protection coating" coated   aluminum transmitter housing and long neck sensor










J





Remote type stainless steel transmitter and standard neck sensor










K





Remote type stainless steel transmitter and long neck sensor

Ex approval











NN00




None











KF21




ATEX, explosion group IIC and IIIC











KF22




ATEX, explosion group IIB and IIIC











SF21




IECEx, explosion group IIC and IIIC











SF22




IECEx, explosion group IIB and IIIC











GF21




EAC Ex, explosion group IIC and IIIC











GF22




EAC Ex, explosion group IIB and IIIC











FF11




FM, groups A, B, C, D, E, F, G











FF12




FM, groups C, D, E, F, G











UF21




INMETRO, explosion group IIC and IIIC











UF22




INMETRO, explosion group IIB and IIIC











NF21




NEPSI, explosion group IIC and IIIC











NF22




NEPSI, explosion group IIB and IIIC











PF21




Korea Ex, explosion group IIC and IIIC











PF22




Korea Ex, explosion group IIB and IIIC

Cable entries












2



ANSI ½" NPT












4



ISO M20x1.5

Communication type and I/O













JA


active current   output HART,1 passive pulse or status output













JB


2 active current   outputs one with HART,2 passive pulse or status outputs













JC


2 active current   outputs one with HART,1 passive pulse or status output,1 voltage-free status   input













JD


1 active current   output HART,2 passive pulse or status outputs,1 passive status output













JE


1 active current   output HART,2 passive pulse or status outputs,1 voltage-free status input













JF


1 active current   output HART,1 passive pulse or status output,1 active pulse or status output   with pull-up resistor,1 voltage-free status input













JG


1 active current   output HART,1 passive pulse or status output,1 active pulse or status   output,1 voltage-free status input













JH


1 active current   output HART,1 passive pulse or status output,1 passive current output,1   active current input













JJ


1 active current   output HART,2 passive pulse or status outputs,1 active current input













JK


1 active current   output HART,1 passive pulse or status output,1 voltage-free status input,1   active current input













JL


1 active current   output HART,1 passive pulse or status output,1 passive current output,1   passive current input













JM


1 active current   output HART, 2 passive pulse or status outputs,1 passive current input













JN


1 active current   output HART,1 passive pulse or status output,1 voltage-free status input,1   passive current input













JP


2 passive   current outputs one with HART,1 passive pulse or status output













JQ


2 passive   current outputs one with HART,2 passive pulse or status outputs













JR


2 passive   current outputs one with HART,1 passive NAMUR pulse or status output













JS


2 passive   current outputs one with HART,2 passive NAMUR pulse or status outputs













M0


Modbus output,1   passive pulse or status output













M2


Modbus output,1   passive pulse or status output,1 active current input













M3


Modbus output, 2   passive pulse or status outputs













M4


Modbus output,1   passive pulse or status output, 1 active pulse or status output













M5


Modbus output, 1   passive pulse or status output, 1 active pulse or status output with pull-up   resistor













M6


Modbus output,1   passive pulse or status output, 1 active current output













M7


Modbus output, 1   passive pulse or status output, 1 passive current input

Display














0

No display














1

With display

Optional codes

/Optional codes

8. Model selection of Supreme 39

Main Code

Suffix Codes

Description

RC















Always RC

Transmitter

E














Essential (base function)

U














Ultimate (high function)

Sensor


S













Supreme

Meter size



39












Nominal mass flow : 32 t/h (1200   lb/min), Maximum mass flow: 50 t/h (1800 lb/min)

Material of wetted parts




S











Stainless steel 1.4404/316L




H











Ni alloy C-22/2.4602

Process connection size





80










DN80, 3"





1H










DN100, 4"





1Q










DN125, 5"

Process connection type






BA1









ASME flange   class 150, suitable for ASME B16.5, raised face (RF)






BA2









ASME flange   class 300, suitable for ASME B16.5, raised face (RF)






BA4









ASME flange   class 600, suitable for ASME B16.5, raised face (RF)






CA4









ASME flange   class 600, suitable for ASME B16.5, ring joint (RJ)






BD4









EN flange PN 40,   suitable for EN 1092-1 type B1, raised face (RF)






ED4









EN flange PN 40,   suitable for EN 1092-1 type E, spigot






FD4









EN flange PN 40,   suitable for EN 1092-1 type F, recess






GD4









EN flange PN 40,   suitable for EN 1092-1 type D, groove






BD6









EN flange PN   100, suitable for EN 1092-1 type B1, raised face (RF)






ED6









EN flange PN   100, suitable for EN 1092-1 type E, spigot






FD6









EN flange PN   100, suitable for EN 1092-1 type F, recess






GD6









EN flange PN   100, suitable for EN 1092-1 type D, groove






BJ1









JIS flange 10K,   JIS B 2220






BJ2









JIS flange 20K,   JIS B 2220






BP1









JPI flange class   150






BP2









JPI flange class   300






BP4









JPI flange class   600






TG9









Process   connection with internal thread G






TT9









Process   connection with internal thread NPT






HS4









Clamp process   connection according to DIN 32676 series A






HS8









Clamp process connection according to DIN 32676 series C (Tri-Clamp)






HS9









Clamp process   connection according to JIS/ISO 2852

Sensor housing 0material







0








Stainless steel 1.4301/304, 1.4404/316L







1








Stainless steel 1.4404/316L

Process fluid temperature range








0







Standard   integrate: -50 to 150℃ (-58 to 302℉), remote type: -70 to 200 °C (-94 – 392 °F)








2







Mid-range: -70   to 230℃ (-94 to 446℉)








3







High: 0 to 350℃ (32 to 662℉)

Mass flow and density accuracy









E7






Liquid: 0.2 %   maximum mass flow deviation, 4 g/l density deviation









D7






Liquid: 0.15 %   maximum mass flow deviation, 4 g/l density deviation









C6






Liquid: 0.1 %   maximum mass flow deviation, 3 g/l density deviation









C3






Liquid: 0.1 % maximum mass flow   deviation, 1 g/l density deviation









C2






Liquid: 0.1 % maximum mass flow   deviation, 0.5 g/l density deviation









70






Gas: 0.75% maximum mass flow deviation









50






Gas: 0.5% maximum mass flow deviation

Design and housing










0





Integral type with "urethane-cured polyester powder coating"   coated aluminum transmitter housing










2





Integral type with "corrosion protection coating" coated   aluminum transmitter housing










A





Remote type with "urethane-cured polyester powder coating"   coated aluminum transmitter housing and standard neck sensor










B





Remote type with "urethane-cured polyester powder coating"   coated aluminum transmitter housing and long neck sensor










E





Remote type with "corrosion protection coating" coated   aluminum transmitter housing and standard neck sensor










F





Remote type with "corrosion protection coating" coated   aluminum transmitter housing and long neck sensor










J





Remote type stainless steel transmitter and standard neck sensor










K





Remote type stainless steel transmitter and long neck sensor

Ex approval











NN00




None











KF21




ATEX, explosion group IIC and IIIC











KF22




ATEX, explosion group IIB and IIIC











SF21




IECEx, explosion group IIC and IIIC











SF22




IECEx, explosion group IIB and IIIC











GF21




EAC Ex, explosion group IIC and IIIC











GF22




EAC Ex, explosion group IIB and IIIC











FF11




FM, groups A, B, C, D, E, F, G











FF12




FM, groups C, D, E, F, G











UF21




INMETRO, explosion group IIC and IIIC











UF22




INMETRO, explosion group IIB and IIIC











NF21




NEPSI, explosion group IIC and IIIC











NF22




NEPSI, explosion group IIB and IIIC











PF21




Korea Ex, explosion group IIC and IIIC











PF22




Korea Ex, explosion group IIB and IIIC

Cable entries












2



ANSI ½" NPT












4



ISO M20x1.5

Communication type and I/O













JA


active current   output HART,1 passive pulse or status output













JB


2 active current   outputs one with HART,2 passive pulse or status outputs













JC


2 active current   outputs one with HART,1 passive pulse or status output,1 voltage-free status   input













JD


1 active current   output HART,2 passive pulse or status outputs,1 passive status output













JE


1 active current   output HART,2 passive pulse or status outputs,1 voltage-free status input













JF


1 active current   output HART,1 passive pulse or status output,1 active pulse or status output   with pull-up resistor,1 voltage-free status input













JG


1 active current   output HART,1 passive pulse or status output,1 active pulse or status   output,1 voltage-free status input













JH


1 active current   output HART,1 passive pulse or status output,1 passive current output,1   active current input













JJ


1 active current   output HART,2 passive pulse or status outputs,1 active current input













JK


1 active current   output HART,1 passive pulse or status output,1 voltage-free status input,1   active current input













JL


1 active current   output HART,1 passive pulse or status output,1 passive current output,1   passive current input













JM


1 active current   output HART, 2 passive pulse or status outputs,1 passive current input













JN


1 active current   output HART,1 passive pulse or status output,1 voltage-free status input,1   passive current input













JP


2 passive   current outputs one with HART,1 passive pulse or status output













JQ


2 passive   current outputs one with HART,2 passive pulse or status outputs













JR


2 passive   current outputs one with HART,1 passive NAMUR pulse or status output













JS


2 passive   current outputs one with HART,2 passive NAMUR pulse or status outputs













M0


Modbus output,1   passive pulse or status output













M2


Modbus output,1   passive pulse or status output,1 active current input













M3


Modbus output, 2   passive pulse or status outputs













M4


Modbus output,1   passive pulse or status output, 1 active pulse or status output













M5


Modbus output, 1   passive pulse or status output, 1 active pulse or status output with pull-up   resistor













M6


Modbus output,1   passive pulse or status output, 1 active current output













M7


Modbus output, 1   passive pulse or status output, 1 passive current input

Display














0

No display














1

With display

Optional codes

/Optional codes